COMM ONE CALL ACCOUNTING
FAQ Index: Ericcson
ERICCSON SMDR/CDR PHONE SYSTEM SETTINGS
-
6006 - Device type: 7 (unspecified terminal/printer)
-
6007 - Character set: 0 (no conversion)
-
6009 - IOU (except CPU-D4) Baud rate: 10 (2400 Baud)
-
6009 - IOU (CPU-D4) Baud rate: 10 (2400 Baud)
-
6009 - SMU (except CPU-D4) Baud rate: 8 (1200 Baud)
-
6009 - SMU (CPU-D4) Baud rate: 10 (2400 Baud)
-
6011 - Autoselect allowed: Yes (optional)
-
6017 - Mode selection for serial interface - should be RS-232
-
6101 - Set year month day to : YYMMDD
-
6102 - Set Day of Week 1 - Sunday, 7 - Saturday
-
6103 - Set hour minute second: HHMMSS
-
6104 - 12h mode, display - Set it to N for 24 mode
-
6201 - Log internal calls? - Yes
-
6202 - Log incoming calls? - Yes
-
6203 - Block log output? - Yes
-
6204 - Digits to log - Set it to NO
-
6205 - Bar outgoing calls for guest - Yes if you want to stop guest making calls while the pbx memory is full. Usefull for hotels. (optional)
-
6301 - Log outgoing calls? - Yes
-
6302 - Log duration time - Set it to 0 because you can configure it in the application.
-
6303 - Log minimum meter pulses - Should set it to 0
-
6304 - Bar outgoing calls? - Yes if you want to stop the outgoing calls while the calls storage if out of order and the pbx memory is full. (optional)
-
6305 - Dialed number: suppress - Set it to 0 unless you want to strip the last n digits from the dialed number for security reasons.
-
6306 - Log dialed numbers beginning with 0 - Yes.
-
6307 - Log dialed numbers beginning with 1 - Yes.
-
6308 - Log dialed numbers beginning with 2 - Yes.
-
6309 - Log dialed numbers beginning with 3 - Yes.
-
6310 - Log dialed numbers beginning with 4 - Yes.
-
6311 - Log dialed numbers beginning with 5 - Yes.
-
6312 - Log dialed numbers beginning with 6 - Yes.
-
6313 - Log dialed numbers beginning with 7 - Yes.
-
6314 - Log dialed numbers beginning with 8 - Yes.
-
6315 - Log dialed numbers beginning with 9 - Yes.
-
6332 - Log minimum cost - Set it 0
-
6403 - Call/Hotel FLEXIBLE CIL.
-
6404/6407 - Lines per page - Set it to 0
-
6402 - Automatic I/O activation - Set it to 1 minute. (0 means disabled)
-
6701 - I/O Port - Value ppiii where pp is board position and iii is individual number of a V24 (IO unit) port.
-
6702 - Lines/page - Set it to 0
ERICCSON SMDR DATA FIELDS
-
Sequence #
-
Call Time
-
Extension Number
-
Dialed Number
-
Call Duration
-
Call Duration (Seconds)
-
Ring
-
Trunk
-
Sent Number
-
Tag Identifier
-
A-Number
-
Transfer Conditions
-
Call Type
-
Call Direction
Comm One Call Accounting Software
Technical Support
PO Box 759 | 1390 E Meadow Valley Dr
Draper, UT 84020
(800) 771-9182
PBX: Ericcson
Posted: 02/02/2017
Updated: 02/13/2021
Author: Comm One Technical Support